Below is a list of recommended curing times for ETEC materials in the PCA 4000 curing apparatus.
Important: Curing times are subject to change.
Important: * - Testing in progress. Curing times are subject to change.
Industrial
Material | Time (H:MM:SS) | Temp. | Power |
BASF Ultracur3D RG 3280 |
First cycle: 0:15:00 |
60° C | 100% |
Second cycle: 0:15:00 |
60° C | 100% | |
Evonik INFINAM ST 6100 L |
First cycle: 1:00:00 |
Xtreme 8K: 20° C Pro XL: 60° C |
100% |
Second cycle: 1:00:00 |
Xtreme 8K: 20° C Pro XL: 60° C |
100% | |
LOCTITE 3D 3843 | Pro XL and Envision One first cycle: 0:15:00 | 20˚ C | 100% |
Xtreme 8K first cycle: 0:20:00 | 20˚ C | 100% | |
Pro XL and Envision One second cycle: 0:15:00 | 20˚ C | 100% | |
Xtreme 8K second cycle: 0:20:00 | 20˚ C | 100% | |
LOCTITE 3D IND147 HDT230 Tough |
Envision One first cycle: 0:30:00 Xtreme 8K first cycle: 0:20:00 |
Envision One: 60˚ C Xtreme 8K: 20˚ C |
100% |
Envision One second cycle: 0:30:00 Xtreme 8K second cycle: 0:20:00 |
Envision One: 60˚ C Xtreme 8K: 20˚ C |
100% | |
Convection oven: 3:00:00 | 170˚ C | N/A | |
LOCTITE 3D IND405 (Black, Clear) |
Pro XL first cycle: 1:15:00 Xtreme 8K first cycle: 0:30:00 Envision One first cycle: 0:20:00 |
Pro XL: 45˚ C Xtreme 8K and Envision One: 20˚ C |
100% |
Pro XL second cycle: 1:15:00 Xtreme 8K second cycle: 0:30:00 Envision One second cycle: 0:20:00 |
Pro XL: 45˚ C Xtreme 8K and Envision One: 20˚ C |
100% | |
* LOCTITE IND 406 | First cycle: 1:00:00 | 20˚ C | 100% |
Second cycle: 1:00:00 | 20˚ C | 100% | |
Convection oven: 2:00:00 | 140˚ C | N/A | |
* LOCTITE MED 413 | First cycle: 0:20:00 | 20˚ C | 100% |
Second cycle: 0:20:00 | 20˚ C | 100% | |
* E-Rigid Form (Charcoal, Amber) | 0:04:00 | 20˚ C | 100% |
E-Rigid PU | 0:05:00 | 60˚ C | 100% |
Jewelry
Material | Time (H:MM:SS) | Temp. | Power |
PIC 100 | First cycle: 0:15:00 | 60° C | 100% |
Second cycle: 0:15:00 | 60° C | 100% | |
Easy Cast 2.0 | 0:30:00 | 60˚ C | 100% |
EC-3000 | 0:10:00 | 60˚ C | 100% |
EC-500 | 0:30:00 | 60˚ C | 100% |